RAID-1 с помощью hpacucli
OS: Ubuntu 12.04
Ниже показан пример создания массива RAID-1 из двух «свежедобавленных» дисков.
# setarch i686 —uname-2.6 hpacucli
HP Array Configuration Utility CLI 8.70-8.0
Detecting Controllers…Done.
Type «help» for a list of supported commands.
Type «exit» to close the console.
=> ctrl all show config
Smart Array P410i in Slot 0 (Embedded) (sn: 5001438009E15DB0)
array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (465.7 GB, RAID 1, OK)
physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 500 GB, OK)
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 500 GB, OK)
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SAS, 500 GB, OK, spare)
unassigned
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 1 TB, OK)
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SAS, 1 TB, OK)
SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 5001438009E15DBF)
=> ctrl slot=0 create type=ld drives=1I:1:5,2I:1:4 raid=1
=> ctrl slot=0 show config
Smart Array P410i in Slot 0 (Embedded) (sn: 5001438009E15DB0)
array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (465.7 GB, RAID 1, OK)
physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 500 GB, OK)
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 500 GB, OK)
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SAS, 500 GB, OK, spare)
array B (SAS, Unused Space: 0 MB)
logicaldrive 2 (931.5 GB, RAID 1, OK)
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 1 TB, OK)
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SAS, 1 TB, OK)
SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 5001438009E15DBF)
=> quit
Вы можете отслеживать комментарии к этой записи с помощью RSS 2.0. Вы можете оставить комментарий, или использовать trackback с вашего сайта.